Defense Supply Center Richmond B46 Generator Tie In
DCSO RICHMOND DIVISION #1
Update 22 May 2026: Corrected error on page 1 of IFB solicitation. Block 13 now has the X for the bid guarantee. This was called out in FAR 52.228-1. 20% bid guarantee required. See new solicitation document in the attachements. IFB extended to 2 June 2026, end of day. Bid opening 3 June 2026 at 10am. See below. There appears to be a conflict between the one-line diagram on Sheet E-602 and the new work power plan on Sheet E-110 regarding the secondary feeder from XFMR T58 to ATS-B. On E-602, this feeder is identified as 3200.4 (9 sets of 4-#500 KCMIL, 4" conduit), which per the feeder schedule appears to indicate new conduit installation. However, Sheet E-110 references Keynote 2 along the same routing, which directs conductors to be installed within existing underground conduits, consistent with the parallel T57-to-ATS-A feeder identified as 3200.4U. Please confirm whether the T58-to-ATS-B feeder is intended to: Reuse existing underground conduit infrastructure, in which case the feeder designation should read 3200.4U; or Be installed in new conduit, in which case Keynote 2 would not apply to this feeder run. Answer: The intent is to reuse the existing conduit infrastructure for the T58 to ATS-B feeder. That feeder on E-602 should have been identified as 3200.4U. RFI's: All building power outages are to take place on weekends, holiday breaks, or times when there will be no occupants in the building. Correct. As this building will be occupied, we cannot have power interruptions during normal working hours. Please confirm per the site visit comments - Contractor is not required to provide backup generators or backup power for weekend outages to take place. Confirmed. The contractor is not required to provide a backup generator or power for weekend outages. ------------ Update: Revised Attachment 1 - Plans attached. See redaction on page E-001 removing specific language about the portable generator. ------------ Continuation Page Defense Supply Center Richmond (DSCR)
AI proposal generator
Generate a structured solution proposal in 90 seconds
Claude drafts an 8-section bid response — exec summary, technical approach, compliance matrix, indicative pricing, timeline, why-we-win — tailored to your company profile and this exact tender.
Related opportunities
Found via vector similarity
Solicitation: NSN -4240-01-361-1319 Canister
W6QK ACC- DTA
Z--National Park Service - Richmond National Battlefield Park (RICH) - Replace HVA
NER SERVICES MABO (43000)
AH -64 Maintenance and Overhaul (M&O)/Upgrade of Hanger Assembly, FWD Bearing
W6QK ACC-RSA
DSCR B66D Restroom and Conference Room Repairs
DCSO RICHMOND DIVISION #1
Refurbish 138 KV OCB Breaker
INTERNAT. BOUNDARY AND WATER COMM.