H399--OKC Elevator Test and Inspection (Semi Annual and Annual Service)
NETWORK CONTRACT OFFICE 19 (36C259)
This amendment is to provide clarifications and corrections to previously combined synopsis amendment for RFQ 36C25926Q0882 0001 OKC Elevator Test and Inspection (Semi Annual and Annual Service) Amendment 0002 provides further clarification and corrections via the following changes: - Due to some requirement confusion all previously redlined (example) language has been fully removed. - All final language changes have been identified by Dark Red, bolded, and italicized lettering, to include previously blue lettering. - It was brought to our attention that ASME 17.1 was used for new construction. This requirement is for the test and inspection of existing elevator equipment and therefore is governed by ASME 17.2 (Guide for Inspection of Elevators, Escalators, and Moving Walks: Provides inspection procedures and guidance for inspectors) and ASME 17.3 (Safety Code for Existing Elevators and Escalators: Covers safety requirements for elevators and escalators already in service, including modernization and existing-equipment conditions.) - Answer to question 5 and 14 was missing specific ASME QEI-1 certification guidance. Both were amended to include the following clarification language: To be eligible for award, the Contractor shall provide evidence of the following in their Factor I. (Technical capability or quality offered to meet the Government requirement) documents: A. The inspector must meet the qualification requirements of the ANSI/ASME QEI-1 certification. Inspectors must be certified by an organization accredited by ANSI/ASME in accordance with the requirements of ANSI/ASME QEI-1 and the contractor must provide proof of QEI-1 certification for their inspectors. A copy of the certificates must be provided with the proposals. All work performed under this contract must be accomplished by QEI-1 Certified Inspectors with the COR and a Certified Elevator Technician. - Answers to questions 6 and 13 were a bit contradictory. Answers amended to read as follows: The VA
AI proposal generator
Generate a structured solution proposal in 90 seconds
Kimi drafts an 8-section bid response — exec summary, technical approach, compliance matrix, indicative pricing, timeline, why-we-win — tailored to your company profile and this exact tender.
Related opportunities
Similar tenders
Silver Creek IRSC
Pike and San Isabel National Forest
FCC Yazoo City Emergency Medical Transport Vehicle (Mini-Ambulance Cart) - Health Services
FCC YAZOO CITY
Purchase custom proto type coating removal tool
NAVAL RESEARCH LABORATORY
J036--Automatic and Roll Up Doors Maintenance, Repairs and Service - NJHCS East Orange VAMC, Lyons VAMC
242-NETWORK CONTRACT OFFICE 02 (36C242)
J036--Automatic and Roll Up Doors Maintenance, Repairs and Service - NJHCS East Orange VAMC, Lyons VAMC
242-NETWORK CONTRACT OFFICE 02 (36C242)
Free tender alerts
Get a weekly digest of United States tenders
New United States tenders matching your interests, delivered to your inbox once a week — no app required. Add keywords and we'll filter the digest to match.