Correct Electrical Deficiencies
246-NETWORK CONTRACTING OFFICE 6 (36C246)
SOW 565-22-500 Correct Electrical Deficiencies Fayetteville VAMC Intent The project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. Period of performance 1,174 calendar days. Medium Voltage VA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope: Replace existing medium voltage entrance equipment with new at campus entrance. Provide new building: Slab on grade, brick on CMU wall, Slate roof tile (to match existing facility) Provide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 . Demo and remove old VA owned medium voltage entrance metal shack. Replace medium voltage sectionalized switch. Provide new metal-clad switchgear with draw-out vacuum circuit breakers. Replace medium voltage oil filled transformer (1) Panel Replacement and Branch Circuit Improvements Correct deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o All work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include: Replace-in-same-room building entrance and large distribution equipment: Normal (service entrance) Switchboards: approx. 2 Generator switchboards: approx. 2 Automatic transfer switch: approx. 7 Replace-in-place distribution panels and panelboards distribution equipment Distribution Panels: approx. 5 P
AI proposal generator
Generate a structured solution proposal in 90 seconds
Kimi drafts an 8-section bid response — exec summary, technical approach, compliance matrix, indicative pricing, timeline, why-we-win — tailored to your company profile and this exact tender.
Related opportunities
Similar tenders
Sole Source OEM Hirsch Software Service Agreement
NAVSUP FLT LOG CTR PUGET SOUND
Z1DA--NRM-CON-663A4-27-001 Under Dispenser Containment (UDC) and sump installation at VAMC American Lake
260-NETWORK CONTRACT OFFICE 20 (36C260)
On-Site Equipment Calibration Services
NAVAL AIR WARFARE CENTER
A Virtual Network to Investigate the Clinical Epidemiology of Influenza and the Effectiveness of Influenza Vaccines
CDC OFFICE OF ACQUISITION SERVICES
Notice of Intent to Award Sole Source - Chestnut Ridge Foam Inc.
NAVSUP FLT LOG CTR SAN DIEGO
Free tender alerts
Get a weekly digest of United States tenders
New United States tenders matching your interests, delivered to your inbox once a week — no app required. Add keywords and we'll filter the digest to match.