Public tenders
Tenders
Live results from every procurement portal we monitor. Refine the search using the filter bar above.
107,177 matching · page 781 of 4,466
59--CABLE ASSEMBLY,RADIO FREQUENCY
DLA AVIATION
VALVE, BUTTERFLY
DLA AVIATION AT OKLAHOMA CITY, OK
Synopsis PR: FD2030-27-00162 1. Estimated issue date and estimated closing/response date: Issue: 23 OCT 2026 Closes: 23 NOV 2026 2. RFP# SPRTA1-27-R-0034 3. Service/Spare/Repair/OH: Spares 4. AMC: 3/B 5. Nomenclature/Noun: Butterfly Valve 6. NSN: 4810-01-146-0722 7. PN: 420955 8. History: 9 Aug 2023, 63 each, Jamaica Bearings Co., Inc. (04836) 9. Description/Function: THE VALVE ASSY. IS A PRESSUREACTUATED VALVE. IT IS SOLENOID CONTROLLED, 32VDC USED FOR ENGINE BLE STARTER FOR ENGINE STARTING. OPERATES AT -65 DEGREES F. TO +300 DEGREES F. WITH AMBIENT PRESSURE OF 1.69 TO 15 PSIA. DIMENTIONS, 8.50 INCH LONG BY 5.65 INCH WIDE BY 3.86 INCH TALL. Weight, 3.75 lbs. MATERIAL CONTENT, VARIOUS METALS AND ELECTRICAL SOLENOID (ALUMINUM, CORROSION RESISTANT STEEL AND CASTINGS) 10. Total Line-Item Quantity: L/I 0001 - 37 Each (Range: 10-56) 11. Application (Engine or Aircraft): KC-135 12. Destination: L/I 0001 Ship to SW3211 13. Required Delivery: L/I 0001 Ship To SW3211, On or Before 7 OCT 2029 14. Qualification Requirements: Do not exist. 15. Export Control Requirements: No 16. UID: Note to Contractor: UID requirements will apply. 17. Qualified Sources: Meggitt North Hollywood, Inc. (CAGE 79318) 18. Set-aside: This acquisition will not be set aside. 19. Mandatory Language: The Government does not own the data or the rights to the data needed to manufacture this item. Firms interested in participating in this procurement are encouraged to contact the OEM to inquire about the data or rights to the data. In accordance with FAR 5.207(c) (16) (i), all responsible sources may submit a bid, proposal, or quotation which shall be considered by the agency. Foreign owned firms are advised to contact the contracting officer or program manager before submitting a proposal to determine whether there are restrictions on receiving an award. It is suggested that small business firms or others interested in subcontracting opportunities in connection with the described procurement make contract
Valve,Regulating,Fl
DLA AVIATION AT OKLAHOMA CITY, OK
See attached solicitation.
Integrated OR System Maintenance
DEFENSE HEALTH AGENCY
AWARD NOTICE AND PUBLIC DISCLOSURE OF SOLE SOURCE JUSTIFICATION in accordance with (IAW) FAR 5.301, FAR 6.305, and FAR Part 12, the Defense Health Agency (DHA), DHA Contracting Activity (DHACA), Healthcare Contracting Division (HCD) - South, has awarded a Firm-Fixed-Price commercial sole source contract under 41 U.S.C. 3304(a)(l) / FAR 6.302-1 ("Only One Responsible Source") Contract Number: HT940826PE032, Solicitation / Notice ID: HT940826QE038, Contractor: Karl Storz Endoscopy-America, Inc. Total Award Value: $798,435.00 (Base Year+ Four 12-Month Option Years) Performance Period: October 15, 2026 - October 14, 2031 (if option exercised). Place of Performance: William Beaumont Army Medical Center (WBAMC), 18511 Highlander Medics Street, Fort Bliss, TX 79906. Requirement Summary- This requirement is for the procurement of software support services for the Karl Storz Integrated OR System. J&A public avail pursuant to FAR 6.305(a), the redacted Justification and Approval (J&A) is attached and will remain accessible for a minimum of 30 days. This notice is for informational purposes only. Inquiries: Contract Specialist Joseph Flores (joseph.a.flores.civ@health.mil) or Contracting Officer Jorge M. Canavati (jorge.m.canavati.civ@health.mil)
F--Emergency and Rapid Response Services VI (ERRS)
REGION 5 CONTRACTING OFFICE
Region 5; Emergency and Rapid Response Services (ERRS) VI
Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC
244-NETWORK CONTRACT OFFICE 4 (36C244)
642-22-104, 36C24426R0088, Upgrade Substation Building 2, Phase 1, PHL CMCVAMC Proposal Due Date: 11/20/2026 at 4:00pm EST. Email proposals to Kevin Rodgers at kevin.rodgers2@va.gov. Corporal Michael J. Crescenz Medical Center (CMC VAMC) requires replacement of Electrical Substations 1 and 2 in order to increase electrical capacity to support future facility projects. The existing substations are approximately 29 years old and require replacement to support current and future electrical demands. This project will replace Electrical Substations 1 and 2 with new 480/277V substations each containing a 1500 kVA transformer. A temporary 480/277V substation with a 1500 kVA transformer shall be installed to maintain electrical service to the facility during demolition and construction activities. Upon completion of construction, the temporary substation shall remain installed as a spare substation for the facility. All work shall be phased to minimize service outages and maintain continuous operation of the medical center. Defined and issued bid documents (drawings and specifications) will serve as the basis of this construction project.
J072--NFS Kitchen Pot & Pan Room Equipment Procurement and Install WASHINGTON DC VAMC-SOLE SOURCE
245-NETWORK CONTRACT OFFICE 5 (36C245)
NFS Kitchen Pot & Pan Room Equipment Procurement and Installation Washington DC VA Medical Center (DCVAMC) Station 688 50 Irving Street NW, Washington, DC 20422 | SOLE SOURCE
H999--Underground Fuel Storage Tank Cleaning, Inspection, Testing and Re-Fueling
261-NETWORK CONTRACT OFFICE 21 (36C261)
See solicitation SOW and attachments
ROBMC Interpreter Equipment
W2SD FEST NAU1 EUROPE
This requirement is for a total of twelve (12) sets, Brand Name, Unite Interpreter Equipment for USACE Europe District. Additionally, USACE Europe District requires two (2) Sennheiser headset microphones. Each set consists of twenty (20) Digital Bodypack Receiver, twenty (20) Single-Ear Headphone, two (2) Digital Bodypack Transmitter, and One (1) Charging and Transport Case.
Cape Canaveral Moving Services
FA2521 45 CONS LGC
The purpose of this Statement of Work (SOW) is to outline the scope, deliverables, and responsibilities for the relocation of gear, machinery, and storage equipment from two existing warehouses (Bldgs. 54938/54805; 15160 Scrub Jay St Cape Canaveral Space Force Station, FL 32920) into an adjacent facility (Hangar AO; 60530 Hangar Rd Cape Canaveral Space Force Station, FL 32920) that is approximately 1/4 mile away. This project requires careful inventory management, safe transport of delicate machinery, and precise placement to ensure minimal operational downtime for Detachment 3. Equipment to be moved includes, but is not limited to: sewing machines, cargo parachutes, personnel parachutes, boat motors, floatation rafts, Vidmar/toolboxes, supply cabinets, printers, storage lockers, and air drop-able rescue equipment packages that consist of jet skis and boats. The target move-in date is 2 November 2026. (Target move in date is an outdated figure. Please disregard this detail in the statement of work.) The government is instead requesting completion as soon as possible and no later than 30 days after award. See statement of work (SOW) attachment for full project description. Site Visit for this effort is mandatory as the governmnet will not be proving measurements of buildings and items to be transported. Contractors are responsible to take all nessecary measurements themselves. AMENDMENT 1 - CHANGES - Updated instances of time zone EST to EDT in the soliciation. - Updated soliciation due date. - Added QnA (Questions and Answers) Document 1 answering common vendor questions.
Request for Information: Outreach and Industry Partnerships (OIP) Portal
SCI TECH ACQ DIV
THIS IS A REQUEST FOR INFORMATION (RFI) ONLY. This RFI is issued solely for information and market research planning purposes. This RFI shall not be construed as an obligation on the part of the Government. This is NOT a Request for Quotations or Proposals. No solicitation document exists, and the Government may or may not issue a formal solicitation as a result of the responses received to this RFI. The Government will not pay for any response or demonstration expenses. All costs incurred responding to this RFI will be solely at the interested party's expense. Failure to respond to this RFI will not preclude participation in any future solicitation. Any information received will become the property of the Government and will not be returned to the submitter. Interested parties are responsible for adequately marking proprietary or sensitive information. The Government’s explicit intent, in this RFI , is to not receive from respondents any proprietary data, trade secrets, business sensitive information, or information considered CONFIDENTIAL under 18 U.S.C. 1905. The Government’s constraint does not in any way relieve interested parties from their responsibility to properly mark proprietary data when it is provided, nor does it alleviate any requirement for the Government to protect marked data. The Government is not obligated to protect unmarked data. The information provided in this RFI is subject to change and is not binding on the Government. All submissions become the property of the Federal Government and will not be returned. Important Notice: Please read attached document for complete instructions on how to respond to this RFI. Interested parties can request a copy of the DRAFT Statement of Work for this requirement by emailing the point of contacts listed below.
Chaplin Priest Services
NAVSUP FLT LOG CTR NORFOLK
Synopsis The Contracting Department, NAVSUP Fleet Logistics Center, Norfolk, VA, 23511-3392 intends to negotiate a Firm Fixed Price type contract. Roman Catholic Priest services are required to meet the Religious Program requirements for Naval Air Station Oceana Chapel and Dam Neck Annex Chapel under OPNAVINST 1730.1E (Religious Ministry within the Department of the Navy). Delivery is FOB Destination and is required not later than 30 days after contract award; Delivery Location is multiple locations in the US. Responsibility and Inspection unless otherwise specified in the order, the supplier is responsible for the performance of all inspection requirements and quality control. The Government will conduct an acceptance inspection at the point of delivery. The North American Industry Classification System (NAICS) code for this acquisition is 813110 with a size standard of $13 million. Potential contractors are hereby notified that the solicitation and subsequent amendments to the solicitation will ONLY be available for download at the above site; this office will no longer issue hard copy solicitations. By submitting a quote, the vendor is self-certifying that neither the requestor nor the principal corporate officials and owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the quote. By submission of a quote, the contractor acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from this solicitation, except for awards to foreign vendors for work to be performed outside the United States. Lack of registration in the SAM database will make a contractor ineligible for award. Contractors may obtain information on registration and annual confirmation requirements by calling 866-606-8220, or via
61--CABLE ASSEMBLY,POWER,ELECTRICAL
DLA AVIATION
53--ANODE,CORROSION PREVENTIVE
DLA LAND AND MARITIME
Protein Palace Proposers Day
DEF ADVANCED RESEARCH PROJECTS AGCY
The Defense Advanced Research Projects Agency (DARPA) will host an in-person Proposers Day in support of the Protein Palace program on November 17, 2026, at the Executive Conference Center, 4075 Wilson Blvd Ste 300, Arlington, VA 22203, from 9:00 a.m. to 4:00 p.m. ET. DARPA anticipates releasing the Protein Palace solicitation prior to Proposers Day. If released, the Protein Palace solicitation will be made available at https://sam.gov/.
SOLICITATION: RLP PACKAGE: The Government is seeking to lease office and related space in FT. LEE, NEW JERSEY for a minimum of 25,939 ANSI/BOMA (ABOA) to a maximum of 27,233 ABOA square feet.
PBS R00 CENTER FOR BROKER SERVICES
The RLP Package is attached for review.
POLYURETHANE COATING (Paints)
W6QK ACC-APG CONT CT TYAD OFC
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A REQUEST FOR PROPOSAL (RFP) TO BE SUBMITTED. IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT. ANY INFORMATION SUBMITTED BY RESPONDENTS TO THIS TECHNICAL DESCRIPTION IS STRICTLY VOLUNTARY. Specifications: ITEM 0001: 383 Green Zenthane, Chemical Agent Resistant (CARC) Polyurethane Topcoat, One Component Size: 1-gallon cans In Accordance With (IAW) Specification: MIL-DTL-53039, Type IV Color: 34094 (Flat Green) Consistency: Liquid Please Note: Upon date of delivery on post, material must have a shelf life of NO LESS THAN 16 months. In addition to CARC specifications, the coating delivered shall be of a climate and season appropriate formulation (i.e. paint received ready for use). For spray application, addition of reducers, reaction retarding agents, or other additives shall not be required. As delivered, the coating must not produce any blisters, foaming or other defects when applied up to 10 mils wet film thickness at temperatures between 60 F. and 85 F. and humidity levels normally encountered in Tobyhanna, PA. The coating must be capable of being applied by roller to the required film thickness above with a maximum of 10% volume addition of a single reducer or VOC exempt retarder. ITEM 0002: Orange Zenthane Plus, Polyurethane Topcoat, Two Component (Part A: 0.75-gal, Part B: 1-quart) Size: 1-gallon kits IAW Specification: MIL-PRF-85285, Type I, Class H and MMS420 Color: 12197 (High Gloss Orange) Consistency: Liquid Please Note: Upon date of delivery on post, material must have a shelf life of NO LESS THAN 14 months. Quick-Dry formulation with capability for application in hot and humid conditions with no/mi
Overhaul Anti-Ice Valve
AVIATION LOGISTICS CENTER (ALC)(00038)
A00001 - The response date for this Contract Opportunity has been extended until November 3, 2026 at 2:00 PM EDT. This is a combined synopsis/solicitation for commercial items prepared in accordance with (IAW) the format in Federal Acquisition Regulation (FAR) subpart 12.201, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. Solicitation number 70Z03826QJ0000367 is issued as a Request for Quotation (RFQ). This solicitation document and incorporated provisions and clauses are those in effect as of November 28, 2025, IAW the Revolutionary FAR Overhaul (RFO). The applicable North American Industry Classification Standard Code is 336413. The small business size standard is 1,250 employees. This is an unrestricted requirement. All responsible sources may submit a quotation which shall be considered by the agency. It is anticipated that a firm-fixed price purchase order will be awarded for the overhual of the Anti-Ice Valves on a competitive basis as a result of this synopsis/solicitation. Pricing should be provided on Attachment 1 – Schedule-70Z03826QJ0000367. At the time of award, the United States Coast Guard (USCG) intends to have four (4) overhauls completed for the components/items specified in the schedule. The USCG may require an additional quantity of twenty-five (25) overhauls completed for a maximum quantity of twenty-nine (29) overhauls completed at the same price and same lead time as the original order, for up to three hundred and sixty-five (365) days after the initial award date. ****Please note that if the USCG chooses to exercise any optional quantity modifications, such modifications will be issued unilaterally to the contractor. The Original Equipment Manufacturer (OEM) of this item is General Electric Company (Cage Code 99207) or Honeywell International (Cage Code 59364). All overhauls shall be performed
Market Intelligence - Progressive Design-Build - Blood Donation Center
US ARMY ENGINEER DISTRICT MOBILE
Progressive Design-Build Blood Donation Center (BDC) and Specialty Medical Departments, Yokota Air Base Hospital, Japan This is not a Request for Proposal (RFQ), only a Request for Information (RFI). No agreement or contract will result from this Special Notice. This notice does not constitute any commitment by the Government. Submissions will be evaluated strictly to gauge industry interest and to determine the technical capability of prospective entities to perform the specialized construction work described herein.
J061--Thompson Power Generator Service RFI Intent to Sole Source
249-NETWORK CONTRACT OFFICE 9 (36C249)
Department of Veterans Affairs Tennessee Valley Healthcare System (TVHS) Alvin C. York Campus Intent to Sole Source Thompson Machinery Commerce Corporation The Department of Veterans Affairs intends to issue sole-source firm-fixed priced contract to Thompson Machinery Commerce Corporation, 1245 Bridgestone Pkwy, La Vergne, TN 37086. A sole source procurement will be issued as an Open Market Purchase Order to Thompson Machinery Commerce Corporation. This procurement is being conducted in accordance with FAR RFO 12.102-1(b). In the interest of economy and efficiency, the Original Equipment Manufacturer (Caterpillar Inc.), stated only one exclusive Small Business (SB), Thompson Machinery Commerce Corporation is the only Factory Authorized source for Sales, Service, and Parts for Caterpillar Equipment in Middle & West Tennessee, and Northern Mississippi areas. In addition, All Caterpillar, Inc, software for engine controls and emissions adjustments are proprietary. The NAICS code is 333120 and has a size standard of 1,250 employees for this procurement. Project Requirements: Reoccuring Full-Service Maintenance and Rebuild Contract on the Caterpillar G3520C Generator Set and Associated System. Background: TVHS VA Medical Center a full-service maintenance and rebuild contract on the Caterpillar G3520C Generator Set and Associated Radiator System located in Building 16. The Caterpillar G3520C, Serial # GZL00146 Generator set is a natural gas fueled engine that has very strict maintenance requirements for continuous and reliable operation. The plant has been in operation for over 10 years and has logged 52,299+ hours of operation, the generator set has been under a service contract with Thompson Power/Caterpillar. The generator sets purpose is to provide primary electrical power and steam to the facility to reduce the cost of the electrical utility and increase utility efficiency, it does work. The engine will have an in-frame overhaul based on hours operated and will be un
TYR Tactical Commercial Armor (Brand Name Only)
DLA TROOP SUPPORT
Pre-solicitation/Synopsis – TYR Tactical Commercial Armor (Brand Name Only) DLA Troop Support intends to issue a solicitation for brand‑name TYR Tactical commercial armor under 10 U.S.C. 3204(a)(1), as implemented by Class Deviation 2026‑O0017, DFARS Part 206 (Rev. 2), and RFO 6.103‑1. The anticipated award is a single firm‑fixed‑price IDIQ contract with five 12‑month ordering periods. POC: Maria Aguayo, Contracting Officer DLA Troop Support 700 Robbins Ave., Philadelphia, PA 19111 Email: Maria.Aguayo@dla.mil. Set‑Aside: Not a set‑aside; solicited on a Brand Name Only basis. Codes: PSC 8470; NAICS 315990. Description: NIJ 0101.06 Level II/IIIA concealable armor and Level IV tactical armor for high‑risk missions. Market research and multi-agency evaluations determined that only TYR Tactical products meet 100% of salient characteristics, including female‑specific shaping, load‑bearing suspension frame, MOLLE configuration, four‑way stretch nylon/spandex concealable compression material, Berry Amendment compliance, ESAPI compatibility, and full interoperability with AFOSI‑fielded TYR modular pouches. Award to another source would disrupt agents and render existing AFOSI inventory incompatible. Supplies included are as follows: 8470-01-739-7787 PGC: 00812 PN: TYR-F-ULVCT-K-BC-NFA2/10F-XS Description: TYR Tactical Female Ultra Low Vis Compression Top, Kit, NFA2/10F, XSmall 8470-01-739-7777 PGC: 00812 PN: TYR-F-ULVCT-K-BC-NFA2/10F-SM Description: TYR Tactical Female Ultra Low Vis Compression Top, Kit, NFA2/10F, Small 8470-01-739-7778 PGC: 00812 PN: TYR-F-ULVCT-K-BC-NFA2/10F-MD Description: TYR Tactical Female Ultra Low Vis Compression Top, Kit, NFA2/10F, Medium 8470-01-739-7798 PGC: 00812 PN: TYR-F-ULVCT-K-BC-NFA2/10F-LG Description: TYR Tactical Female Ultra Low Vis Compression Top, Kit, NFA2/10F, Large 8470-01-739-7760 PGC: 00812 PN: TYR-F-ULVCT-K-BC-NFA2/10F-XL Description: TYR Tactical Female Ultra Low Vis Compression Top, Kit, NFA2/10F, XLarge 8470-01-739-7779 PGC: 0
Scintillometer BLS900 Neo, Path Reduction Aperture, Power Supply, Standard and Tall Tripods
W6QM MICC-FT DRUM
The Meteorology Branch at White Sands Missile Range (WSMR) requires the procurement of a Scintillometer and required supplies which are fully detailed in the attached Product Description. If you are proposing an equivalent product, please provide adequate documentation supporting the salient characteristics which meet the requirement.
Control, Generator
DLA AVIATION AT OKLAHOMA CITY, OK
Synopsis PR: FD2030-27-00046 1. Estimated issue date and estimated closing/response date: Issue: October 23, 2026 Closes: November 23, 2026 2. RFP# SPRTA1-27-R-0026 Request for Proposal 3. Service/Spare/Repair/OH: Spares 4. AMC: 3/R 5. Nomenclature/Noun: Control, Generator 6. NSN: 6110-01-165-6844 7. PN: 948F456-4 8. History: 23 Dec 2025, 99 each, Intertrade Limited, (0SVE9) 9. Description/Function: Control, Generator. DIMENSIONS, 15.51 INCH (L) BY 6.05 INCH (W) BY 5.25 INCH (H). 13.5 POUNDS (WEIGHT). MATERIAL CONTENT, Metals and plastics. 10 KVA Generator Control Unit. APPL. TO F-16. 10. Total Line Item Quantity: L/I 0001 22 Each (Range: 6-33) 11. Application (Engine or Aircraft): F-16 12. Destination: Ship to SW3210, Hill AFB, UT 13. Required Delivery: On or Before 02 APR 2031 14. Qualification Requirements: Contractor must be an approved source. 15. Export Control Requirements: No 16. UID: UID requirements will apply. 17. Qualified Sources: Hamilton Sundstrand Corporation (CAGE 99167) 18. Set-aside: This acquisition will not be set aside. 19. Surplus: Surplus is not authorized. 20. Mandatory Language: The Government does not own the data or the rights to the data needed to manufacture this item. Firms interested in participating in this procurement are encouraged to contact the OEM to inquire about the data or rights to the data. In accordance with FAR 5.207(c) (16) (i), all responsible sources may submit a bid, proposal, or quotation which shall be considered by the agency. Foreign owned firms are advised to contact the contracting officer or program manager before submitting a proposal to determine whether there are restrictions on receiving an award. It is suggested that small business firms or others interested in subcontracting opportunities in connection with the described procurement make contract with the firms(s) listed. This acquisition involves technology that has a military or space application. The extent of foreign participation has not yet been det
DataMesh Tender Radar
Win more UK IT & software tenders — one curated email a week
We watch Find a Tender & Contracts Finder so you don't have to. Every Monday you get the new UK IT & software tenders worth bidding on — curated by hand, not scraped and dumped.
- Hand-curated — no keyword spam, no duplicates
- Every notice with its buyer, value, deadline & how to bid
- One email a week — cancel anytime